Polychlorinated Biphenyls Chemical Storage Specifications

Compliant storage and rental solutions for Polychlorinated Biphenyls (C12H10-nCln). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Non-flammableNon-Flammable Storage

Chemical formula

About Polychlorinated Biphenyls

PCBs have been used as coolants and lubricants in transformers, capacitors, and other electrical equipment because they don't burn easily and are good insulators. The manufacture of PCBs was stopped in the U.S. in 1977 because of evidence they build up in the environment and can cause harmful health effects.

Structured hazard data

Hazard class
See SDS
Storage category
Non-Flammable Storage
Flammable
No
Flash point
>141 o C (285.8 o F)
Storage temperature
Ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
OXIDIZING AGENTS

Specific Target Organ Systemic Toxicity (Repeated Exposure): Category 2 Aquatic Toxicity (Chronic): Category 1

Fire Suppression System

Dry Chemical fire suppression is recommended for Polychlorinated Biphenyls

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Polychlorinated Biphenyls (C12H10-nCln). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: Use fire fighting measures that suit the environment

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Polychlorinated Biphenyls should account for its listed hazards, climate control needs (Ambient), and segregation requirements. OXIDIZING AGENTS

Review How the NFPA 704 hazard rating works when designing fire rating, containment, and building selection.

Properties: Appearance VARY FROM OILY LIQUID TO WHITE CRYSTALLINE SOLID AND NON CRYSTALLINE RESIN Odour MILD AROMATIC ODOUR Odour Threshold NOT AVAILABLE pH NOT AVAILABLE Melting Point NOT AVAILABLE Boiling Point 340°C to 375°C Flash Point NOT AVAILABLE Evaporation Rate NOT AVAILABLE Flammability COMBUSTIBLE

Matched to this chemical

Recommended storage solutions for Polychlorinated Biphenyls

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Non-fire-rated0 HourChemical Storage Shipping

    BoxSAFE CX

    • Non Fire-Rated
    • 8 ft x 40 ft x 8' 5"
    • 50 Qty 55 Gallon Drums
    • 9 Pallets or Totes
    • 302 Square Feet storage
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rated

    • 0-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rate

    • 0-Hour Fire-Rated
    • 8 ft x 20 ft
    • 27 Barrels
    • 55 Gal Storage Drums
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Polychlorinated Biphenyls be stored?

Store Polychlorinated Biphenyls in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: Ambient. Compatibility notes: OXIDIZING AGENTS US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Polychlorinated Biphenyls flammable?

Polychlorinated Biphenyls is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.

What hazard class is Polychlorinated Biphenyls?

Polychlorinated Biphenyls is listed as: Consult the SDS and applicable hazard classification. Specific Target Organ Systemic Toxicity (Repeated Exposure): Category 2 Aquatic Toxicity (Chronic): Category 1

What fire suppression is recommended for Polychlorinated Biphenyls?

Dry Chemical fire suppression is generally recommended for Polychlorinated Biphenyls (C12H10-nCln). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Polychlorinated Biphenyls storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Polychlorinated Biphenyls. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.